EPH CONTROLS TR1V2-TR2V2 射频电源开关

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-product

规格

  • 电源供应: 200 – 240VAC 50-60Hz
  • 聯絡評分: 230 伏交流电 10(3)A
  • 环境温度: 0…45°C
  • 自动动作: Type 1. C.
  • 家电类别: II 类器具EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-1
  • 污染程度: 污染等级 2
  • IP 等级: IP20
  • 额定脉冲电压tage: 耐卷tag符合 EN 2500 的浪涌 60730V

TR1 TR2V2 的工作原理

  • Your TR1 TR2V2 is used to send a wireless signal from one location to another when running Cables is difficult, expensive, or otherwise not an option.
  • The product comprises two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
  • When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes, which sends voltage from Live out on the TR2V2.
  • It is possible to send a wireless signal in one direction or both.
  • When a signal is sent from the TR1V2 to the TR2V2, a green light will activate on the TR2V2.
  • When the TR2V2 sends a signal to the TR1V2, a green light will activate on the TR1V2.
  • Common uses include sending a signal from a programmer to a boiler or hot water cylinder that is in a different location. These are also used to control pump overrun and many other applications.
  • It is possible to have more than one set of TR1, TR2V, 2and, where required.
  • Please see pages 9-13 for wiring examp莱斯

TR1TR2V2内部接线图

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-2警告: Installation should only be carried out by a qualified person and by wiring regulations.

Switching  Options

电源开关

  • Link L to 3

低音量tag电子切换

  • Remove the external controls link from the boiler PCB.
  • Connect 2 and 3 to these terminals.

安装

  1. The TRIV2 should be wall-mounted in an area within 30 metres of the TR2V2. Both TRIV2 & TR2V2 must be mounted more than 25cm away from metal objects, as this will affect communication. The TRIV2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave, ve, or wireless network adapter. They can be fitted to
    1. Single-gang recessed back box.
    2. 表面安装盒
    3. Directly mounted on a wall.
  2. Use a Phillips screwdriver to loosen the screws of the backplate on the bottom of the TRIV2 & TR2V2, lift upwards from the bottom, and remove the backplate.
  3. Screw the backplate to the wall with the screws provided.
  4. 按照接线图对背板进行接线。
  5. Mount the TRIV2 & TR2V2 on the backplate, making sure the pins and the backplatcontactsts are making a sound connection. Push the TRIV2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom.m

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-3EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-4

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-5

按钮/LED 说明

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-6

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7手动的 Press to activate or deactivate the Live out terminal.
EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8连接 Hold for 3 seconds to initialise the pairing process. The RF light will flash.
EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-9重置 Press to reset the T, R1, TR2V2.
笔记: The connection procedure is not required as both TR1 & TR2V2 are pre-paired

LED 说明

引领 颜色 描述
LED 直播 红色的 没有卷tage on the Live terminal.
绿色的 有卷tage 在 Live in 终端上 - 现在 RF 信号将被发送到另一个 RF 主开关以激活 Live out 终端。
射频LED 白色的 白色 LED 常亮表示恒温器已连接。
当恒温器断开连接时,RF 灯将双闪。检查恒温器配对。
             笔记: 当系统发送和接收通信信号时,RF 灯将间歇闪烁。
            笔记: The RF light will blink once every second when in RF pairing by holding Connect. Press the Manual to exit from this state.
直播 LED 红色的 尚未从其他 RF 主开关接收到 RF 激活信号。
绿色的 RF activation signal has been received from the other RF Mains Switch.

To connect the TRI TR2V2
请注意: When installing TRI TR2V2 RF mains switches, both TRI &TR2V2 are pre-paired. The procedures below are not required.

On TR1V2:

  • 抓住 EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.

On TR2V2:

  • 抓住 EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8持续 3 秒。
  • The RF LED will begin to flash, and the Live out LED will appear solid green.
  • When connected, all three LEDs will appear solid.

On TR1V2:

  • EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7to exit the pairing mode.
  • After connecting successfully, the RF LED on both TR1V2 & TR2V2will appear solid.

To disconnect the TRI TR2V2

  • 抓住 EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.
  • 抓住 EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 10 seconds until the Live in LED appears solid red.

On TR2V2:

  • 抓住 EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.
  • 抓住 EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8Connect for 10 seconds until the Live in & Live out LED appears solid red.

On TRIV2:

  • EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7退出。
  • The TRI TR2V2 is now disconnected.

接线防爆amp莱斯

Example  One way RF Switch: Programmer to Boiler – Mains Switching

TR1V2 
On TR1, when Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.

TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the boiler.EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-11

安装说明

  1. Mains Switching Boiler
  2. 低音量tage Switching Boiler
  • 在 TR2V2 上
  • On the boiler PCB
  • 在 TR2V2 上
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.

Example 2 Two Two-way RF Switch:

  1. Programmer to Motorised Valve
  2. Motorised Valve to Boiler – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out contact closes, sending 230V to activate the boiler.

TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-12

安装说明

1. Main Switching Boiler
2. 低音量tage Switching Boiler
3. 电动阀

  • On the TRIV2
  • On the boiler PCB
  • On the TRIV2
  • 在 TR2V2 上
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the motorised valve.

Examp乐 3 One way RF Switch:
Pump Overrun – Mains Switching

TR 1 v2

  • On TRI, when Live in receives 230V from the boiler, TRI sends a wireless signal to TR2.

TR2V2

On TR2, the COM & Live out contact closes, sending 230V to activate the pump.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-13

安装说明

  • 泵开
  • the TR2V2
  • Link L to 3 to power the Live out terminal to the pump

Examp乐 4 Two Two-way RF Switch: Pump Overrun

  1. 程序员到锅炉
  2. Boiler to Pump – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out contact closes, sending 230V to activate the pump.

TR2V2

  • On TR2, the COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-14安装说明

  1. Mains Switching Boiler
  2. 低音量tage Switching Boiler
  • 在 TR2V2 上
  • On the boiler PCB –
  • 在 TR2V2 上
  • On the TRIV2
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the pump.

Examp乐 5 Two Two-way RF Switch: Unvented Cylinder:

  1. 高限温控器编程器
  2. Motorised Valve to Boiler – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out the contact closes, sending 230V to activate the boiler.

TR2V2

On TR2, the COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-15安装说明

  1. Mains Switching Boiler
  2. 低音量tage Switching Boiler
  3. 上限温控器
  4. 电动阀
  • On the TRIV2
  • On the boiler PCB
  • 在 TR2V2 上
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the High Limit thermostat.

EPH 控件 IE
技术@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
cork, Tl 2 W665EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-16

EPH 控制英国
技术@ephcontrols.co.uk
www.ephcontrols.co.uk/
联系我们
+44 1933 322 072
Harrow, HAI IBDEPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-17

常见问题解答

Q: Can I install the TR1, TR2V2V2 devices myself?
A: Installation should only be carried out by a qualified person following wiring regulations to ensure safety and proper functionality.

问:TR1V2 和 TR2V2 之间有效通信的最大距离是多少?
A: The recommended distance is within 30 meters for optimal wireless signal transmission.

文件/资源

EPH CONTROLS TR1V2-TR2V2 射频电源开关 [pdf] 使用说明书
TR1V2、TR2V2、TR1V2-TR2V2 射频电源开关、TR1V2-TR2V2、射频电源开关、电源开关、开关